Mumbai

'easy hand pumping'

Items tagged with 'easy hand pumping'

product image
Hydrothermal Autoclave

Hydrothermal Autoclave: - Make: HE (NSIC REGD, ISO 9001 – 2015/14001-2015/13485-2016/FDA/ GMP/CE CERTIFIED) Description: The Hydrothermal Autoclave Reactor use to carry hydrothermal reaction at high pressure and high temperature. Hydrothermal synthesis reactor generally comes in a two variety; the first is Polytetrafluoroethylene (PTFE) lined hydrothermal autoclave reactors. Hydrothermal reactor mainly made up of two parts; outer high-quality stainless-steel (304 & 316 Customer on Demand) jacket and inner PTFE liner chamber. In the Teflon-lined autoclave, the reaction is carried out at maximum 260-degree Celsius (500 Fahrenheit), while the safe temperature is 260-degree Celsius. This product extensively used in the scientific laboratory, research and development labs, institutional organizations, quality analysis section in industries etc. Specifications of PTFE Lined Autoclave: • Hydrothermal Autoclave: 2000 ml, • Maximum operating temperature: ≤260°C • Working temperature: – 240°C • Working Pressure: ≤3MPa or 30 Bar • Heating and Cooling Rate: ≤5°C/min • Material: Shell made of high-quality nonmagnetic 304 stainless steel • Easy to handle • Threads are very smooth to lock and unlock • Can be customized as per requirement • Primary screw type cap for basic tightening • Secondary cap has been provided at the top of the reactor thorough (Allen Key Bolt) for extra tightening to avoid leakage • Customized stainless-steel jacket/autoclave of SS 316 can also be provided if needed, which is better for corrosive materials.

Send Message
product image
Hydrothermal Autoclave

Hydrothermal Autoclave: - Make: HE (NSIC REGD, ISO 9001 – 2015/14001-2015/13485-2016/FDA/ GMP/CE CERTIFIED) Description: The Hydrothermal Autoclave Reactor use to carry hydrothermal reaction at high pressure and high temperature. Hydrothermal synthesis reactor generally comes in a two variety; the first is Polytetrafluoroethylene (PTFE) lined hydrothermal autoclave reactors. Hydrothermal reactor mainly made up of two parts; outer high-quality stainless-steel (304 & 316 Customer on Demand) jacket and inner PTFE liner chamber. In the Teflon-lined autoclave, the reaction is carried out at maximum 260-degree Celsius (500 Fahrenheit), while the safe temperature is 260-degree Celsius. This product extensively used in the scientific laboratory, research and development labs, institutional organizations, quality analysis section in industries etc. Specifications of PTFE Lined Autoclave: • Hydrothermal Autoclave: 1000 ml, • Maximum operating temperature: ≤260°C • Working temperature: – 240°C • Working Pressure: ≤3MPa or 30 Bar • Heating and Cooling Rate: ≤5°C/min • Material: Shell made of high-quality nonmagnetic 304 stainless steel • Easy to handle • Threads are very smooth to lock and unlock • Can be customized as per requirement • Primary screw type cap for basic tightening • Secondary cap has been provided at the top of the reactor thorough (Allen Key Bolt) for extra tightening to avoid leakage • Customized stainless-steel jacket/autoclave of SS 316 can also be provided if needed, which is better for corrosive materials.

Send Message
product image
Hydrothermal Autoclave

Hydrothermal Autoclave: - Make: HE (NSIC REGD, ISO 9001 – 2015/14001-2015/13485-2016/FDA/ GMP/CE CERTIFIED) Description: The Hydrothermal Autoclave Reactor use to carry hydrothermal reaction at high pressure and high temperature. Hydrothermal synthesis reactor generally comes in a two variety; the first is Polytetrafluoroethylene (PTFE) lined hydrothermal autoclave reactors. Hydrothermal reactor mainly made up of two parts; outer high-quality stainless-steel (304 & 316 Customer on Demand) jacket and inner PTFE liner chamber. In the Teflon-lined autoclave, the reaction is carried out at maximum 260-degree Celsius (500 Fahrenheit), while the safe temperature is 260-degree Celsius. This product extensively used in the scientific laboratory, research and development labs, institutional organizations, quality analysis section in industries etc. Specifications of PTFE Lined Autoclave: • Hydrothermal Autoclave: 500 ml, • Maximum operating temperature: ≤260°C • Working temperature: – 240°C • Working Pressure: ≤3MPa or 30 Bar • Heating and Cooling Rate: ≤5°C/min • Material: Shell made of high-quality nonmagnetic 304 stainless steel • Easy to handle • Threads are very smooth to lock and unlock • Can be customized as per requirement • Primary screw type cap for basic tightening • Secondary cap has been provided at the top of the reactor thorough (Allen Key Bolt) for extra tightening to avoid leakage • Customized stainless-steel jacket/autoclave of SS 316 can also be provided if needed, which is better for corrosive materials.

Send Message
product image
Hydrothermal Autoclave

Hydrothermal Autoclave: - Make: HE (NSIC REGD, ISO 9001 – 2015/14001-2015/13485-2016/FDA/ GMP/CE CERTIFIED) Description: The Hydrothermal Autoclave Reactor use to carry hydrothermal reaction at high pressure and high temperature. Hydrothermal synthesis reactor generally comes in a two variety; the first is Polytetrafluoroethylene (PTFE) lined hydrothermal autoclave reactors. Hydrothermal reactor mainly made up of two parts; outer high-quality stainless-steel (304 & 316 Customer on Demand) jacket and inner PTFE liner chamber. In the Teflon-lined autoclave, the reaction is carried out at maximum 260-degree Celsius (500 Fahrenheit), while the safe temperature is 260-degree Celsius. This product extensively used in the scientific laboratory, research and development labs, institutional organizations, quality analysis section in industries etc. Specifications of PTFE Lined Autoclave: • Hydrothermal Autoclave: 50 ml, • Maximum operating temperature: ≤260°C • Working temperature: – 240°C • Working Pressure: ≤3MPa or 30 Bar • Heating and Cooling Rate: ≤5°C/min • Material: Shell made of high-quality nonmagnetic 304 stainless steel • Easy to handle • Threads are very smooth to lock and unlock • Can be customized as per requirement • Primary screw type cap for basic tightening • Secondary cap has been provided at the top of the reactor thorough (Allen Key Bolt) for extra tightening to avoid leakage • Customized stainless-steel jacket/autoclave of SS 316 can also be provided if needed, which is better for corrosive materials.

Send Message
product image
Hydrothermal Autoclave

Hydrothermal Autoclave: - Make: HE (NSIC REGD, ISO 9001 – 2015/14001-2015/13485-2016/FDA/ GMP/CE CERTIFIED) Description: The Hydrothermal Autoclave Reactor use to carry hydrothermal reaction at high pressure and high temperature. Hydrothermal synthesis reactor generally comes in a two variety; the first is Polytetrafluoroethylene (PTFE) lined hydrothermal autoclave reactors. Hydrothermal reactor mainly made up of two parts; outer high-quality stainless-steel (304 & 316 Customer on Demand) jacket and inner PTFE liner chamber. In the Teflon-lined autoclave, the reaction is carried out at maximum 260-degree Celsius (500 Fahrenheit), while the safe temperature is 260-degree Celsius. This product extensively used in the scientific laboratory, research and development labs, institutional organizations, quality analysis section in industries etc. Specifications of PTFE Lined Autoclave: • Hydrothermal Autoclave: 200 ml, • Maximum operating temperature: ≤260°C • Working temperature: – 240°C • Working Pressure: ≤3MPa or 30 Bar • Heating and Cooling Rate: ≤5°C/min • Material: Shell made of high-quality nonmagnetic 304 stainless steel • Easy to handle • Threads are very smooth to lock and unlock • Can be customized as per requirement • Primary screw type cap for basic tightening • Secondary cap has been provided at the top of the reactor thorough (Allen Key Bolt) for extra tightening to avoid leakage • Customized stainless-steel jacket/autoclave of SS 316 can also be provided if needed, which is better for corrosive materials. SIZE: 200 ml

Send Message
product image
Hydrothermal Autoclave

Hydrothermal Autoclave: - Make: HE (NSIC REGD, ISO 9001 – 2015/14001-2015/13485-2016/FDA/ GMP/CE CERTIFIED) Description: The Hydrothermal Autoclave Reactor use to carry hydrothermal reaction at high pressure and high temperature. Hydrothermal synthesis reactor generally comes in a two variety; the first is Polytetrafluoroethylene (PTFE) lined hydrothermal autoclave reactors. Hydrothermal reactor mainly made up of two parts; outer high-quality stainless-steel (304 & 316 Customer on Demand) jacket and inner PTFE liner chamber. In the Teflon-lined autoclave, the reaction is carried out at maximum 260-degree Celsius (500 Fahrenheit), while the safe temperature is 260-degree Celsius. This product extensively used in the scientific laboratory, research and development labs, institutional organizations, quality analysis section in industries etc. Specifications of PTFE Lined Autoclave: • Hydrothermal Autoclave: 100 ml, • Maximum operating temperature: ≤260°C • Working temperature: – 240°C • Working Pressure: ≤3MPa or 30 Bar • Heating and Cooling Rate: ≤5°C/min • Material: Shell made of high-quality nonmagnetic 304 stainless steel • Easy to handle • Threads are very smooth to lock and unlock • Can be customized as per requirement • Primary screw type cap for basic tightening • Secondary cap has been provided at the top of the reactor thorough (Allen Key Bolt) for extra tightening to avoid leakage • Customized stainless-steel jacket/autoclave of SS 316 can also be provided if needed, which is better for corrosive materials. SIZE: 100 ml

Send Message
product image
Tube Furnace 1200 C

Application:- 1200°C Tube Furnace (Programmable) is Mainly Provides High Temperature Heat Treatment Environment For Industrial, Research Institutes, Factories And Other Industrial Laboratories, And Is Applied To New Materials Such As Metal Materials, Ceramic Materials, Nano Materials, And Semiconductor Materials. Features:-  The Furnace Tube Adopts Quartz Tube As Carrier And The Light Weight Aluminium Flanges On Its Both Ends Are Simple Design, Reasonable, Easy To Disassemble And Convenient For Entering And Leaving Sintered Samples.  Furnace Material Is High-Purity Ceramic Fiber Zirconia Grade Materials, New Assembly Structure, and No Transformation In Long Term High Temperature, Sturdy And Durable.  Using Intelligent PID Temperature Control Instrument, With 1 Program Function, Can Set The Temperature Rise Curve, Can Be Programmed 16 Segments.  The Machine Will Send Out An Alarm Signal To The Over-Temperature During The Working Process, And Automatically Complete The Protection Action.  The Heating Element Is Made Of Kanthal – A1 Wire, Coil Type With End Connections, Which Can Bear Large Load, Stable And Long Service Life.  High Precision of Temperature Accuracy ±1°C.  The Heating Rate Is Fast, From Room Temperature To 1150 Degrees, Generally Takes 120 Minutes.  Electronic Components Are Used Such as Autonics / Schneider / L&T Brand, it’s safe and Reliable.  The Machine Will Send Out An Alarm Signal To The Over-Temperature During The Working Process, And Automatically Complete The Protection Action.  When The Instrument Program Is Set, Just Press The Run Button And The Next Work Will Be Completed Automatically.  It can be installed with a Gas Mass Rotameter, Manual Precise Control of the Gas. Product Overview:- HE-STF-1200P – Singal Zone Tube Furnace - 1200℃ Series Products Are Mainly Applied For The Heat Treatment Of Samples Under Vacuum Or Protective Atmosphere, High Quality Chamber Materials And Stable Temperature Control System Ensure The Reliability Of Experiment. The Product Uses The Zirconia Grade Ceramic Fiber Material As The Furnace Chamber Material; The Furnace Tube Material Is Fine, And The Tube Is Sealed By Light Weight Aluminium Flanges On Its Both Ends, The Furnace Can Be Work Under The Vacuum, There Are Air Inlet And Air Outlet On The Flange, Also It Can Be Filled In Protective Air, The Precision Needle-Valve May Adjust The Air Inlet Flow Rate. Specification:- Type Two Zone Split Type Max Temperature 1200℃ Continue Operating Temp. 1150℃ Heating Element Kanthal “A-1” Wire in Coil Form Insulation  First layer: 1430℃ ceramic fiber board& Zirconia Fiber Blanket.  Second layer: 1260℃ ceramic fiber board & Zirconia Fiber Blanket.  High Quality Ceramic Fiber Zirconia Grade Thermal Insulation Material to Ensure A Good Uniformity Temperature Accuracy ±1℃ Thermocouple K type (Pt-Rh to Pt-Rh) with 99.7% purity Alumina tube Temperature Controller  PID automatic control via SSR power control with phase angle fired, current limiting resistor.  1 programmable x 16 segments for precise control of heating rate, cooling rate and dwell time.  Built in PID Auto-Tune function with overheating & broken thermocouple broken protection for this Split Tube Furnace 1200 type.  Over temperature protection and alarm allows for operation without attendant Electronic Component Autonics / Schneider / L&T Electronics Brands Heating Rate ≤ 15℃/Min (Suggest 10℃/Min For Longer Life Using of Furnace) Safety Protection Overheat And Thermocouple-Break Alarm Certification NSIC Regd, ISO 9001 – 2015/14001-2015/13485-2016/FDA/GMP/CE Certified Furnace Shell High Quality GI Sheet With PP Powder Coated Accessories One Pair of High Temperature Furnace Gloves One No of Bot Tong and Operational Manual Optional Quartz / Alumina Bot Warranty  One-year limited warranty for this Split Tube Furnace 1200 type with lifetime support. (Consumable parts such as heating elements and Sensor, crucibles are not covered by the warranty, please order the replacement at related products) ATTENTION: Any damages caused by the use of corrosive and acidic gases are not under the coverage of One Year Limited Warranty. Using Attentions  The cooling rate of this Split Tube Furnace 1200 type shall also not exceed 8℃ /min.  Toxic or explosive gases are not recommended for use with this Split Tube Furnace without necessary safety controls and supervision.  Small cracks may appear on the surface of the refractory ceramics over extended use. This is a normal occurrence Model Hot Zone Length 1 power Supply HE-STF-1200P 300 mm 220 V/ 5 KW Single Phase

Send Message

Still searching for
easy hand pumping?